American access system ADV-1000 Operations Instructions Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
Page 9 © American Access Systems
WIRING CONNECTIONS
1. The DK unit is designed to operate between 11.5 volts minimum and 29 volts AC maximum. Using a
multi-meter, measure the supply line voltage to make sure it falls within these tolerances.
IMPORTANT: TURN OFF THE POWER SUPPLY BEFORE MAKING ELECTRICAL CONNECTIONS
2. Locate the two white wires on the circuit board main harness and, WITH THE POWER OFF, connect
them to the power supply leads. Use wire nuts or connectors to secure the connections. The DK
unit is rectified. Polarity need not be observed.
3. Connect the primary device to be controlled to the unit’s primary relay control leads.
a. If you are connecting to a gate operator or electric door strike, use the BROWN and
ORANGE leads for normally open contact. (Refer to the Wiring Diagrams, page 5.)
b. If you are connecting to a mag-lock or any device that requires power in the locked state,
use the BROWN and BLUE leads for normally closed contact. (Refer to the Wiring Diagrams,
page 5.)
c. If you interface with a secondary device, connect the unit’s secondary relay control leads
to the secondary device. (Refer to the Wiring Diagrams, page 5.)
4. Connect the Green lead to Earth Ground.
5. Before supplying power to the unit, refer to the appropriate wiring diagram to double- check all
connections. When you are sure you have the unit wired correctly, apply power to the unit.
a. If this is the FIRST TIME POWER UP, the unit will perform a self-diagnostics routine. After each
test has passed, the unit will respond with a tone. The unit will perform a total of 4 tests
(depending upon the equipment connected to the unit.) The unit will then flash the LED's
several times while it is performing a memory setup.
b. Once all the tests have passed and the unit is set up correctly, you will hear a “GOOD
TONE” (an oscillating high tone) from the unit. If the unit does not perform as above, quickly
shut off power to the unit and contact your distributor or American Access Systems.
NOTE: The unit will perform a self-diagnostics routine only during first-time power up. After first-time power
up, the unit will sound a “GOOD TONE” (an oscillating high tone) each time power is applied.
Page view 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 23 24

Comments to this Manuals

No comments

Ibico IB410192 manuali

Manuali dei proprietari e guide per l'utente per Calcolatrici Ibico IB410192.
We fornisce 1 manuali pdf Ibico IB410192 per scaricare gratuitamente in base al tipo di documento: Scheda Tecnica


Ibico IB410192 Scheda Tecnica (1 pagine)


Marchio: Ibico | Categoria: Calculators | Dimensione: 0.12 MB |

 




Più prodotti e manuali per Calcolatrici Ibico

Modelli Tipo di Documento
IB081X Scheda Tecnica   Ibico Calculator 081X, 1 pagine
IB1221X Scheda Tecnica   Ibico Calculator 1221X, 1 pagine
IB210X Scheda Tecnica   GBC Calculator 210X, 1 pagine